ORIGINAL ARTICLE
Year : 2015  |  Volume : 9  |  Issue : 3  |  Page : 337-342  

Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine


1 Department of Anaesthesiology, S.M.S. Medical College, Jaipur, Rajasthan, India
2 Department of Anaesthesiology, All Institute of Medical Sciences, Jodhpur, Rajasthan, India

Date of Web Publication8-Sep-2015

Correspondence Address:
Nitesh Gill
Department of Anaesthesiology, S.M.S. Medical College, Jaipur, Rajasthan
India
Login to access the Email id

Source of Support: Nil, Conflict of Interest: None declared.


DOI: 10.4103/0259-1162.158013

Rights and Permissions
   Abstract 

Background: Intubation is known to cause an exaggerated hemodynamic response in the form of tachycardia, hypertension, and dysrhythmias. In cervical spine instability, intubation has to be performed using cervical immobilization to prevent exacerbation of spinal cord injuries. Application of rigid cervical collar may reduce cervical spine movements, but it hinders tracheal intubation with a standard laryngoscope. The aim of this study was to compare the hemodynamic responses to fiberoptic bronchoscope (FOB) and McCoy laryngoscope in patients undergoing elective surgery under general anesthesia with rigid cervical collar simulating cervical spine immobilization in the situation of cervical trauma. Methods: Thirty-two patients in the age range 20–50 years, of American Society of Anaesthesiologist I-II, and of either sex undergoing elective surgery under general anesthesia were randomly allocated into each group. There were two groups according to the technique used for intubation: Group A (flexible FOB) and Group B (McCoy laryngoscope). Systolic blood pressure, diastolic blood pressure, mean arterial blood pressure and heart rate (HR) were recorded at baseline, intraoperatively, immediately before and after induction, and immediately after intubation. Thereafter, every min for next 5 min. Statistical Analysis: Intergroup comparison of categorical data was done by Chi-square test. P < 0.05 was considered statistically significant. Intergroup comparison of quantitative data was done by the parametric test (unpaired t-test), and probability was considered to be significant if <0.05. Results: Due to intubation response, HR and blood pressure increased significantly (P < 0.05) above preoperative values in McCoy group as compared to the fiberoptic group. Conclusion: We suggest that the flexible FOB is an effective and better method of intubation in a situation like traumatic cervical spine injury and provides stable hemodynamics.

Keywords: Fiberoptic bronchoscope, hemodynamic response, intubation, McCoy laryngoscope


How to cite this article:
Gill N, Purohit S, Kalra P, Lall T, Khare A. Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine. Anesth Essays Res 2015;9:337-42

How to cite this URL:
Gill N, Purohit S, Kalra P, Lall T, Khare A. Comparison of hemodynamic responses to intubation: Flexible fiberoptic bronchoscope versus McCoy laryngoscope in presence of rigid cervical collar simulating cervical immobilization for traumatic cervical spine. Anesth Essays Res [serial online] 2015 [cited 2018 Jul 22];9:337-42. Available from: http://www.aeronline.org/text.asp?2015/9/3/337/158013




   Introduction Top


In anesthesia, intubation is an essential artistry for an anesthesiologist during airway management. With the use of the conventional approach of intubation, exaggerated hemodynamic response occurs which is due to forces exerted by laryngoscope blade for visualization of glottic opening. These hemodynamic changes manifest as increase in heart rate (HR), arterial blood pressure, and arrhythmias which can cause detrimental cardiovascular and neurological effects specially in vulnerable patients e.g., those with ischemic heart disease, cerebrovascular disease, etc.[1] Any technique for intubation requires lesser lifting force would proportionally reduce the sympathetic discharge, and hence changes in HR and blood pressure.[2] For obtundation of this hemodynamic response, various interventions (pharmacological[3],[4] and nonpharmacological[5],[6]) have been tried.

During intubation in cervical spine trauma victims, adequate cervical immobilization (in the form of manual inline axial stabilization or application of rigid cervical collar) is prime and foremost task to avoid devastating neurological outcomes.[7] Intubation in these patients is a significant challenging task for an experienced anesthesiologist. In cervical spine instability, sufficient laryngeal exposure during intubation requires movement of cervical vertebrae in form of flexion of cervical spine and extension of atlanto-occipital joint, but to prevent aggravation of cord injury, intubation has to be performed with cervical immobilization, hence both objectives are contradictory.[8] Use of rigid cervical collar may reduce cervical spine movement, but it significantly reduces the mouth opening, making laryngoscopy difficult and also lifts up the chin and tips the larynx anteriorly.[9],[10]

Devices such as fiberoptic bronchoscope (FOB) and McCoy laryngoscope are very useful in such difficult intubation situations and obtund hemodynamic response of intubation.

In the situation of difficult intubations, flexible FOB is considered as gold standard.[11] With the help of flexion-deflexion movement of distal flexi tip, the operator can visualize the airway structures nearly at 360° along with the rotational movement of fiberscope. It reduces the stress response to intubation due to less mechanical stimulation of laryngeal surface. Many studies have compared the cardiovascular response to laryngoscopy and fiberoptic intubation.[12],[13],[14],[15],[16]

McCoy laryngoscope (Penlon Ltd., Abingdon, England) is a modified Macintosh laryngoscope, introduced in 1993[17] as an aid for difficult tracheal intubations.[18] With the help of lever on the back of the handle, hinged tip of McCoy blade allows elevation of the epiglottis which ultimately reduces the amount of force required and improves the view of glottis.[19] It was found as a very useful tool of laryngoscopy in limited neck extension in several studies.[20],[21],[22]

The primary objective of this clinical study was to investigate whether there is clinically significant difference between the hemodynamic response to orotracheal intubation, guided by either of the devices (flexible FOB and McCoy laryngoscope) in patients undergoing elective surgery under general anesthesia with rigid cervical collar simulating cervical spine immobilization in the situation of cervical trauma, in terms of: Systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP), and HR. The secondary objectives were to compare intubation duration and glottic visualization with the use of either of the two devices.


   Methods Top


This hospital-based randomized comparative interventional type of study was conducted between February 1, 2014 and January 31, 2015. After obtaining approval of the Institution Ethical Committee and written informed consent from the patient, 64 American Society of Anaesthesiologist (ASA) physical status I and II patients of either gender between 20 and 50 years of age scheduled for elective procedures under general anesthesia and required endotracheal intubation were included in this study. Exclusion criteria included patient's refusal, ASA physical status III, IV, V, anticipated difficult intubation (Mallampatti grade 4, thyromental distance <6 cm, sternomental distance <12 cm, mentohyoid distance <5 cm, neck circumference >42 cm), a history of reactive airway disease, gastro-esophageal reflux, hypertension, dysrhythmia, cervical spine pathology, airway distortion or trauma, morbid obesity, major organ dysfunction and use of medication that affect blood pressure and HR. Patients were divided into two groups of 32 each according to the technique used for intubation: Group A - Flexible FOB (n = 32) and Group B - McCoy laryngoscope (n = 32). Patients were assigned randomly into these two groups using chit in box method.

All the patients were examined on the day before surgery with routine investigations under the institutional protocol and explained about the anesthetic technique and perioperative course. Preoperatively, all the patients were fasted adequately (8 h fasting) and were normothermic. In the operation theater, the rigid cervical collar was applied, and intravenous (i.v.) lines with 18/20 gauge cannula were secured. Standard monitoring included noninvasive arterial pressure, electrocardiography, oxygen saturation, end tidal carbon dioxide (EtCO2), and measurement of volatile anesthetic levels. After 15 min of stabilization period, baseline readings of HR, SBP, DBP, and MAP were recorded.

Premedication with glycopyrrolate (0.005 mg/kg i.v.) and fentanyl citrate (2 µg/kg i.v.) was given along with preoxygenation for 5 min. Patients were induced with propofol 2 mg/kg infused i.v. slowly over 1 min, followed by injection of neuromuscular blocking agent-rocuronium 1 mg/kg i.v. after checking the adequacy of mask ventilation. Patients were ventilated with face mask with 1% isoflurane in oxygen for 2 min. If any difficulty was encountered in mask ventilation, the patient was excluded from the study.

After 2 min of the administration of muscle relaxant, tracheal intubation was performed with endotracheal tube (ETT) (male - 8.0 mm ID, female - 7.5 mm ID) either by flexible FOB or by McCoy laryngoscope. While using FOB for oral intubation, modified Berman's airway was used as an aid and the tip of the bronchoscope was not advanced too deep into the trachea to avoid stimulation of the carina. Tube position was checked by auscultation and confirmed by EtCO2 tracings. After successful tracheal intubation, the lungs were mechanically ventilated for the duration of the procedure and anesthesia was maintained with isoflurane in a mixture of N2O and O2.

All values of HR and BP (SBP, DBP, and MAP) were recorded before induction of anesthesia, immediately after induction, just after intubation, and thereafter, every minute for next 5 min. No other medications were administered, or manipulations (including any movement of the head and neck and preparation of the operative field) were performed during the 5 min data collection period after tracheal intubation. The duration of the tracheal intubation procedure was noted. The duration of the intubation attempt is defined as the time taken from insertion of the blade/fiberoptic cord between the teeth until the ETT is placed through the vocal cords, as evidenced by visual confirmation by the anesthesiologist. Glottic view was categorized as: (i) Complete glottis (ii) posterior glottis only (iii) epiglottis only (iv) no glottis and epiglottis. All the intubations were performed by a single anesthesiologist who was familiar and trained with intubation using McCoy laryngoscope and FOB. Any patient who required more than one attempt to achieve successful intubation was excluded from the study. Due to the nature of the study, only single blinding was possible; however, the person recording the hemodynamic parameters was unconnected to the study.

Statistical analysis

A pilot study on 20 patients, 10 in each group, was conducted after obtaining approval of the Institution Ethical Committee and written informed consent from the patient. The results were analyzed with the aid of a statistician, and a sample size of 32 in each group was calculated with alpha error 0.05 and power 80%. Analysis of the statistical data obtained from the study was carried out by statistical programming software Statistical Package for the Social Sciences - SPSS Statistics version 17.0.0 (SPSS Inc., Chicago, Illinois, USA). SPSS is a statistical tool used to analyze and correlate social data. Categorical data (sex, ASA grade, Mallampati grade and glottic view) are presented as numbers and intergroup comparison of these was done by Chi-square test. P < 0.05 was considered statistically significant. Quantitative data, that is, age, weight, airway parameters, intubation duration, and hemodynamic variables (HR, SBP, DBP, and MAP) are presented as mean value and standard deviation. Intergroup comparison of continuous data was done by the parametric test (unpaired t-test), and statistical significance was considered at P < 0.05.


   Results Top


The demographic data and airway characteristics of patients were insignificantly (P > 0.05) different between Group A (FOB) and Group B (McCoy) as shown in [Table 1]. While intubation duration shown in [Figure 1] was significantly (P < 0.05) higher in Group A in comparison to Group B and glottic view shown in [Figure 2] was significantly (P < 0.05) less clear in Group B as compared to Group A.
Table 1: Intergroup comparison of demographic data, airway characteristics and intubation duration

Click here to view
Figure 1: Intubation durations (in seconds) with flexible fiberoptic bronchoscope and McCoy laryngoscope

Click here to view
Figure 2: Glottic view with flexible fiberoptic bronchoscope and McCoy laryngoscope

Click here to view


Hemodynamic parameters are shown in [Table 2]. HR and blood pressure (SBP, DBP and MAP) were comparable at baseline in both groups (P > 0.05). [Figure 3] shows the mean of the SBP, DBP, and MAP of the patients at preinduction, postinduction, just after intubation and thereafter, every minute for next 5 min. It shows that in McCoy group, SBP, DBP, and MAP increases significantly (P < 0.05) after intubation and lasts up to 5 min as compared to the fiberoptic group. [Figure 4] shows the HR of patients at preinduction, postinduction, just after intubation and thereafter, every minute for next 5 min. The increase in HR was statistically significant (P < 0.05) in McCoy group as compared to FOB group up to 1 min after intubation.
Table 2: Comparison of hemodynamic parameters in between fiberoptic group (FOB) and McCoy group (McCoy) at different time points

Click here to view
Figure 3: Blood pressure (in mmHg) response to intubation with flexible fiberoptic bronchoscope and McCoy laryngoscope at various time points

Click here to view
Figure 4: Heart rate (in beat per min) response to intubation with flexible fiberoptic bronchoscope and McCoy laryngoscope at various time points

Click here to view


The endotracheal intubation was successfully performed in a single attempt in all the patients without any failure. There was no esophageal intubation with both devices. There was no incidence of dental or more severe airway laceration or any other complications with the use of both the devices.


   Discussion Top


Efforts to blunt circulatory response to tracheal intubation in situ ations such as cervical immobilization have prompted the development of several alternative methods, with more focus on pharmacological methods as compared to nonpharmacological methods. In this study, we aimed to evaluate the relative efficacy of flexible FOB and McCoy laryngoscope when used by experienced anesthesiologist in the clinical setting of simulation of cervical immobilization using rigid cervical collar, in terms of cardiovascular response to intubation.

According to study of McCoy et al.[19] use of McCoy laryngoscope reduces the force required for better laryngoscopy by lifting epiglottis and ultimately reduces the stress response to laryngoscopy. Nishiyama et al.,[5] Tewari et al.,[23] and Haidry and Khan[24] compared McCoy and Macintosh blades and showed that the use of McCoy blade resulted in a lesser change in HR and BP. On other side, some studies[25],[26],[27] did not find any significant difference in the circulatory response between McCoy blade and Macintosh blade.

Adachi et al.[12],[13] and Barak et al.[14] compared fiberoptic intubation with conventional direct laryngoscopy and found stable hemodynamics with the fiberoptic group. While Shibata et al.[16] found that the cardiovascular responses to oral fiberoptic intubation are less severe than those to the nasal approach and recommended oral approach, especially in patients with coronary artery disease, taking into consideration the cardiovascular responses to fiberoptic intubation and similarly Cook et al.[28] also reported hemodynamic stability and less morbidity with fiberoptic oral intubation.

We have demonstrated that both flexible FOB and McCoy laryngoscope offer high success rates when difficult airways are simulated by the application of a rigid cervical collar. Our study demonstrated that with the use of flexible FOB, there was a significantly lesser change in HR and all kind of pressure readings (SBP, DBP, MAP) due to intubation in comparison to McCoy blade group. Although in McCoy group significant increase in pressure readings lasts for at least 5 min, significant increase of HR only lasts for 1–2 min. With better centralization of FOB's distal flexi-tip, we can minimize the stimulation of the laryngeal surface and as a result of this minimal change in cardiovascular variables. Less sympathetic stimulation with FOB can be of clinical benefit as less dose of drugs will be required to attenuate this response thereby decreasing the side effects associated with drugs like potent narcotics.

In patients where neck is stabilized in a neutral position, the McCoy laryngoscope improves the view of glottic opening.[20],[21],[22] While fiberoptic provides a nearby complete view of the larynx. Our study demonstrated that in McCoy group, full glottic view was presented in 56% of group population and only posterior glottis was visible in 44% of group population while with fiberoptic, complete view of glottis was seen in 100% of group population. In our study, we also found that intubation duration was significantly less in McCoy group (17.9 s ± 3.07) as compared to fiberoptic group (40 s ± 7.28). Various studies of McCoy[2],[8],[24] and FOB[14],[29] showed variability in terms of intubation duration as it depends on the skill of specialist.

We did experience some difficulty during railroading of ETT over insertion cord during oral intubation. Asai et al.,[30] Katsnelson et al.,[31] and Schwartz et al.[32] reported the same problem in their studies. We solved this problem by 90° anticlockwise rotation of the tube over cord or keeping Murphy's eye anteriorly. Several studies[32],[33],[34] have confirmed that 90° anticlockwise rotation of the tube decreases the difficulty in railroading of tube over fiberoptic cord. Although we were concerned that view through fiberoptic might become obstructed by secretion or fogging, neither problem was observed.


   Conclusion Top


We conclude that although, with McCoy laryngoscope, intubation can be performed more swiftly in situ ation of emergency as compared to fiberscope, but in a situation of cervical immobilization which is utmost priority to avoid further neurological injury or fracture instability in cervical trauma, as far as stable hemodynamic response to intubation and glottis visualization are concerned, FOB is superior device over McCoy laryngoscope, if available.

 
   References Top

1.
Shribman AJ, Smith G, Achola KJ. Cardiovascular and catecholamine responses to laryngoscopy with and without tracheal intubation. Br J Anaesth 1987;59:295-9.  Back to cited text no. 1
    
2.
Joseph J, Sequeira T, Upadya M. Comparison of the use of McCoy and TruView EVO2 laryngoscopes in patients with cervical spine immobilization. Saudi J Anaesth 2012;6:248-53.  Back to cited text no. 2
[PUBMED]  Medknow Journal  
3.
Casati A, Fanelli G, Albertin A, Deni F, Danelli G, Grifoni F, et al. Small doses of remifentanil or sufentanil for blunting cardiovascular changes induced by tracheal intubation: A double-blind comparison. Eur J Anaesthesiol 2001;18:108-12.  Back to cited text no. 3
    
4.
Vucevic M, Purdy GM, Ellis FR. Esmolol hydrochloride for management of the cardiovascular stress responses to laryngoscopy and tracheal intubation. Br J Anaesth 1992;68:529-30.  Back to cited text no. 4
    
5.
Nishiyama T, Higashizawa T, Bito H, Konishi A, Sakai T. Which laryngoscope is the most stressful in laryngoscopy; Macintosh, Miller, or McCoy? Masui 1997;46:1519-24.  Back to cited text no. 5
    
6.
Wood ML, Forrest ET. The haemodynamic response to the insertion of the laryngeal mask airway: A comparison with laryngoscopy and tracheal intubation. Acta Anaesthesiol Scand 1994;38:510-3.  Back to cited text no. 6
    
7.
Hastings RH, Kelley SD. Neurologic deterioration associated with airway management in a cervical spine-injured patient. Anesthesiology 1993;78:580-3.  Back to cited text no. 7
    
8.
Durga P, Kaur J, Ahmed SY, Kaniti G, Ramachandran G. Comparison of tracheal intubation using the Airtraq(®) and Mc Coy laryngoscope in the presence of rigid cervical collar simulating cervical immobilisation for traumatic cervical spine injury. Indian J Anaesth 2012;56:529-34.  Back to cited text no. 8
[PUBMED]  Medknow Journal  
9.
Goutcher CM, Lochhead V. Reduction in mouth opening with semi-rigid cervical collars. Br J Anaesth 2005;95:344-8.  Back to cited text no. 9
    
10.
Wakeling HG, Nightingale J. The intubating laryngeal mask airway does not facilitate tracheal intubation in the presence of a neck collar in simulated trauma. Br J Anaesth 2000;84:254-6.  Back to cited text no. 10
    
11.
Ovassapian A. The flexible bronchoscope. A tool for anesthesiologists. Clin Chest Med 2001;22:281-99.  Back to cited text no. 11
    
12.
Adachi YU, Takamatsu I, Watanabe K, Uchihashi Y, Higuchi H, Satoh T. Evaluation of the cardiovascular responses to fiberoptic orotracheal intubation with television monitoring: Comparison with conventional direct laryngoscopy. J Clin Anesth 2000;12:503-8.  Back to cited text no. 12
    
13.
Adachi YU, Satomoto M, Higuchi H, Watanabe K. Fentanyl attenuates the hemodynamic response to endotracheal intubation more than the response to laryngoscopy. Anesth Analg 2002;95:233-7.  Back to cited text no. 13
    
14.
Barak M, Ziser A, Greenberg A, Lischinsky S, Rosenberg B. Hemodynamic and catecholamine response to tracheal intubation: Direct laryngoscopy compared with fiberoptic intubation. J Clin Anesth 2003;15:132-6.  Back to cited text no. 14
    
15.
Smith JE, King MJ, Yanny HF, Pottinger KA, Pomirska MB. Effect of fentanyl on the circulatory responses to orotracheal fibreoptic intubation. Anaesthesia 1992;47:20-3.  Back to cited text no. 15
    
16.
Shibata Y, Okamoto K, Matsumoto M, Suzuki K, Sadanaga M, Morioka T. Cardiovascular responses to fiberoptic intubation: A comparison of orotracheal and nasotracheal intubation. J Anesth 1992;6:262-8.  Back to cited text no. 16
    
17.
McCoy EP, Mirakhur RK. The levering laryngoscope. Anaesthesia 1993;48:516-9.  Back to cited text no. 17
    
18.
Sakai T, Konishi A, Nishiyama T, Higashizawa T, Bito H. A comparison of the grade of laryngeal visualisation; – The McCoy compared with the Macintosh and the Miller blade in adults. Masui 1998;47:998-1001.  Back to cited text no. 18
    
19.
McCoy EP, Mirakhur RK, McCloskey BV. A comparison of the stress response to laryngoscopy. The Macintosh versus the McCoy blade. Anaesthesia 1995;50:943-6.  Back to cited text no. 19
    
20.
Gabbott DA. Laryngoscopy using the McCoy laryngoscope after application of a cervical collar. Anaesthesia 1996;51:812-4.  Back to cited text no. 20
    
21.
Uchida T, Hikawa Y, Saito Y, Yasuda K. The McCoy levering laryngoscope in patients with limited neck extension. Can J Anaesth 1997;44:674-6.  Back to cited text no. 21
    
22.
Laurent SC, de Melo AE, Alexander-Williams JM. The use of the McCoy laryngoscope in patients with simulated cervical spine injuries. Anaesthesia 1996;51:74-5.  Back to cited text no. 22
    
23.
Tewari P, Gupta D, Kumar A, Singh U. Opioid sparing during endotracheal intubation using McCoy laryngoscope in neurosurgical patients: The comparison of haemodynamic changes with Macintosh blade in a randomized trial. J Postgrad Med 2005;51:260-4.  Back to cited text no. 23
[PUBMED]  Medknow Journal  
24.
Haidry MA, Khan FA. Comparison of hemodynamic response to tracheal intubation with Macintosh and McCoy laryngoscopes. J Anaesthesiol Clin Pharmacol 2013;29:196-9.  Back to cited text no. 24
[PUBMED]  Medknow Journal  
25.
Han TS, Kin JA, Park NG, Lee SM, Cho HS, Chung IS. A comparison of the effects of different type of laryngoscope on haemodynamics. McCoy versus the Macintosh blade. Korean J Anesthesiol 1999;37:398-41.  Back to cited text no. 25
    
26.
Román J, Beltrán de Heredia B, García-Velasco P, Parramón F, García R, Vilaplana J, et al. Hemodynamic response to intubation with Macintosh and McCoy blades. Rev Esp Anestesiol Reanim 1996;43:177-9.  Back to cited text no. 26
    
27.
Shimoda O, Ikuta Y, Isayama S, Sakamoto M, Terasaki H. Skin vasomotor reflex induced by laryngoscopy: Comparison of the McCoy and Macintosh blades. Br J Anaesth 1997;79:714-8.  Back to cited text no. 27
    
28.
Cook JA, Ramsay CR, Fayers P. Using the literature to quantify the learning curve: A case study. Int J Technol Assess Health Care 2007;23:255-60.  Back to cited text no. 28
    
29.
Gupta K, Girdhar KK, Anand R, Majgi SM, Gupta SP, Gupta PB. Comparison of haemodynamic responses to intubation: Flexible fibreoptic bronchoscope versus bonfils rigid intubation endoscope. Indian J Anaesth 2012;56:353-8.  Back to cited text no. 29
[PUBMED]  Medknow Journal  
30.
Asai T, Murao K, Johmura S, Shingu K. Effect of cricoid pressure on the ease of fibrescope-aided tracheal intubation. Anaesthesia 2002;57:909-13.  Back to cited text no. 30
    
31.
Katsnelson T, Frost EA, Farcon E, Goldiner PL. When the endotracheal tube will not pass over the flexible fiberoptic bronchoscope. Anesthesiology 1992;76:151-2.  Back to cited text no. 31
    
32.
Schwartz D, Johnson C, Roberts J. A maneuver to facilitate flexible fiberoptic intubation. Anesthesiology 1989;71:470-1.  Back to cited text no. 32
    
33.
Hughes S, Smith JE. Nasotracheal tube placement over the fibreoptic laryngoscope. Anaesthesia 1996;51:1026-8.  Back to cited text no. 33
    
34.
Koga K, Asai T, Latto IP, Vaughan RS. Effect of the size of a tracheal tube and the efficacy of the use of the laryngeal mask for fibrescope-aided tracheal intubation. Anaesthesia 1997;52:131-5.  Back to cited text no. 34
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4]
 
 
    Tables

  [Table 1], [Table 2]


This article has been cited by
1 Evaluation of Endotracheal Intubation with a Flexible Fiberoptic Bronchoscope in Lateral Patient Positioning: A Prospective Randomized Controlled Trial
Hui Li,Wu Wang,Ya-Ping Lu,Yan Wang,Li-Hua Chen,Li-Pei Lei,Xiang-Ming Fang
Chinese Medical Journal. 2016; 129(17): 2045
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Methods
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1303    
    Printed40    
    Emailed0    
    PDF Downloaded121    
    Comments [Add]    
    Cited by others 1    

Recommend this journal