Anesthesia: Essays and Researches  Login  | Users Online: 220 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Home | About us | Editorial board | Ahead of print | Search | Current Issue | Archives | Submit article | Instructions | Copyright form | Subscribe | Advertise | Contacts
ORIGINAL ARTICLE
Year : 2019  |  Volume : 13  |  Issue : 2  |  Page : 248-253

Efficacy of stroke volume variation, cardiac output and cardiac index as predictors of fluid responsiveness using minimally invasive vigileo device in intracranial surgeries


Department of Anaesthesiology, Siddhartha Medical College, Vijayawada, Andhra Pradesh, India

Correspondence Address:
Santhi Sree Mulam
Dr. No. 13-2-2, D1 Apt, Sai Krishna Towers, Latchiraju Street, Opp NGO Home, Suryaraopeta, Kakinada - 533 002, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aer.AER_10_19

Rights and Permissions

Introduction: Functional hemodynamic monitoring using dynamic parameters such as stroke volume variations (SVVs) based on pulse contour analysis is considered more accurate than central venous pressure and mean arterial pressure (MAP) in predicting fluid responsiveness. New device, i.e., Vigileo system, allows automatic and continuous monitoring of cardiac output (CO) based on pulse contour analysis and respiratory stroke volume. Aim: The study aims to test the above hypothesis using graded volume loading step (VLS) to assess the accuracy of SVV as a predictor of fluid responsiveness in patients undergoing intracranial surgery. Materials and Methods: After taking ethical committee approval and informed consent, 60 patients aged between 18 and 55 years belonging to the American Society of Anesthesiologists physical status Class I and II, of either sex, scheduled for brain surgery were included in the study. In this study, 5 min after intubation, with stable hemodynamics, patients received volume loading in successive steps (VLS) of 200 ml of lactated Ringer's solution until the stroke volume increased to <10%. Blood pressure (BP), heart rate (HR), stroke volume (SV), and SVV were measured before and after each VLS. Optimal preload augmentation required by each patient was measured by the number of VLS after which an increase in SV was <10%. Results: There was a significant decrease in the baseline BP and SV in responsive and nonresponsive groups for the first VLS, but there is no change in HR statistically. There was a significant change in SV after first VLS. Receiver operating characteristic analysis showed a larger area under the curve of 0.758 for SVV compared to other measured variables. The median number of VLS administered were 2 per patient equating to a mean ± SD requirement of 368 ± 176 ml of crystalloid per patient as the optimal preoperative infusion volume. Conclusion: SVV is a better predictor of preload responsiveness measured with third-generation Vigileo device when compared to BP and HR.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed579    
    Printed25    
    Emailed0    
    PDF Downloaded47    
    Comments [Add]    

Recommend this journal