Anesthesia: Essays and Researches  Login  | Users Online: 1655 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Home | About us | Editorial board | Ahead of print | Search | Current Issue | Archives | Submit article | Instructions | Copyright form | Subscribe | Advertise | Contacts
ORIGINAL ARTICLE
Year : 2020  |  Volume : 14  |  Issue : 1  |  Page : 154-159

Study of tidal volume and positive end-expiratory pressure on alveolar recruitment using spiro dynamics in mechanically ventilated patients


Department of Anesthesia and Critical Care, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

Correspondence Address:
Dr. Virendra Kumar
Department of Anesthesia and Critical Care, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aer.AER_10_20

Rights and Permissions

Background and Aims: Ventilator setting in the intensive care unit patients is a topic of debate and setting of tidal volume (TV) should be patient-specific based on lung mechanics. In this study, we have evaluated to develop optimal ventilator strategies through continuous and thorough monitoring of respiratory mechanics during ongoing ventilator support to prevent alveolar collapse and alveolar injury in mechanically ventilated patients. Methods: In our monocentric, randomized, observational study, we had recruited 60 patients and divided them into two groups of 30 each. In Group 1 patients, TV and positive end-expiratory pressure (PEEP) were set according to pressure–volume (P/V) curve obtained by the mechanical ventilator in a conventional manner (control group), and in Group 2, TV and PEEP were set according to P/V curve obtained by the mechanical ventilator using intratracheal catheter. PEEP and TV were set accordingly. TV, PEEP, and PaO2/FiO2(P/F) ratio at days 1, 3, and 7, mortality within 7 days and mortality within 28 days were measured in each group and compared. Results: We found a significant difference between PEEP and P/F ratio in both groups while intragroup comparison at days 1, 3, and 7. After the intergroup comparison of Group 1 and 2, we observed a significant difference of PEEP and P/F ratio between the groups at day 7 and not on day 1 or 3. Conclusion: This study concludes that optimal PEEP is more accurate using an intratracheal catheter than the conventional method of deciding ventilator setting. Hence, it is recommended to use intratracheal catheter to obtain more accurate ventilator settings.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed34    
    Printed0    
    Emailed0    
    PDF Downloaded7    
    Comments [Add]    

Recommend this journal