Comparative evaluation of mcgrath MAC, Truview video laryngoscopes and Macintosh laryngoscope for endotracheal intubation in patients undergoing surgery under general anaesthesia


1 Department of Anaesthesiology, Dayanand Medical College and Hospital, Ludhiana, Punjab, India
2 Department of Anaesthesiology and Intensive Care, Acharya Shri Chander College of Medical Sciences and Hospital, Jammu, Jammu and Kashmir, India
3 Dhingra Child Care Center, Ludhiana, Punjab, India

Date of Submission23-Feb-2020
Date of Decision15-Mar-2020
Date of Acceptance17-Mar-2020
Date of Web Publication22-Jun-2020

Correspondence Address:
Sunana Gupta
Department of Anaesthesiology and Intensive Care, Acharya Shri Chander College of Medical Sciences and Hospital, Sidhra, Jammu, Jammu and Kashmir
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aer.AER_16_20

Rights and Permissions
   Abstract 


Background: Videolaryngoscopy is a newly developed technique to improve tracheal intubation success. It was made to bypass the need of directly visualising the glottic inlet. These devices are advantageous as there is no need of aligning the laryngeal, pharyngeal and oral axes for a clear view, thus making intubation easier and faster. Aim and Objectives: Primary objective of the study was to determine the duration of laryngoscopy and intubation and Cormack - Lehane grading when intubating with McGrath MAC, Truview video laryngoscope and Macintosh laryngoscope. Secondary objectives of the study were to determine the number of attempts and optimization manouveres required to intubate. Materials and Methods: This study was conducted on total of 120 patients in age 20-70 years, either sex, with American Society of Anaesthesiologists physical status classes I or II scheduled for elective surgery under general anaesthesia. They were randomly assigned equally to group 1, 2 and 3 (n = 40) to be intubated by Mcgrath MAC video laryngoscope, Truview video laryngoscope and Macintosh laryngoscope respectively. Parameters recorded were duration of laryngoscopy and intubation, Cormack Lahane grading, ease of intubation, number of attempts and optimisation manouveres required for intubation. Statistical Analysis: Comparison of mean value among the three groups was done using student t test and percentage comparison was done using chi square test. To compare more than two variables ANOVA test was used. The P values of less than 0.05 was considered statistically significant. Results: Duration of laryngoscopy was significantly less in McGrath MAC group when compared to Truview group (P = 0.02) and to Macintosh group (P < 0.001) and the duration of intubation was comparable among all three study groups (P > 0.05). The difference in Cormack - Lehane grading was not significant between McGgrath MAC and Trueview (P = 0.71) but was significant between McGrath MAC and Macintosh (P = 0.002) and Trueview and Macintosh (P = 0.002). Ease of intubation was better in McGrath MAC and Truview groups compared to Macintosh group (P < 0.05). Intubation was successful in the first attempt in 39 (97.50%) patients in McGrath MAC group, 40 (100%) patients in Truview group and 35 (87.50%) patients in Macintosh group. McGrath MAC and Truview groups performed better with respect to optimization manoeuvres compared to Macintosh group (P < 0.05). Trauma was observed in 2 (5%) patients in Truview group and 5 (12.50%) patients in Macintosh group. In McGrath MAC group, no patient underwent any trauma. Conclusion: Although duration of laryngoscopy was significantly shorter in McGrath as compared to Truview video laryngoscope and Macintosh laryngoscope but the duration of intubation was comparable between the three groups. Both these video laryngoscopes performed significantly better than Macintosh laryngoscope with respect to laryngoscopic view, requirement of optimization manoeuvre and need for second attempt for intubation.

Keywords: Machintosh Laryngoscope, McGrath MAC, truview videolaryngoscope


How to cite this article:
Kaur G, Gupta S, Mehta N, Dhingra JS. Comparative evaluation of mcgrath MAC, Truview video laryngoscopes and Macintosh laryngoscope for endotracheal intubation in patients undergoing surgery under general anaesthesia. Anesth Essays Res 2020;14:20-4

How to cite this URL:
Kaur G, Gupta S, Mehta N, Dhingra JS. Comparative evaluation of mcgrath MAC, Truview video laryngoscopes and Macintosh laryngoscope for endotracheal intubation in patients undergoing surgery under general anaesthesia. Anesth Essays Res [serial online] 2020 [cited 2020 Sep 26];14:20-4. Available from: http://www.aeronline.org/text.asp?2020/14/1/20/287394




   Introduction Top


Videolaryngoscopy is a relatively recent development in airway management that attempts to improve the success of tracheal intubation. Videolaryngoscope (VL) contains miniature video cameras enabling the operator to visualize the glottis indirectly. VL places an imaging device toward the distal end of laryngoscope blade. This moves the providers point of view past the tongue, avoiding the need for a direct line of sight to the glottis.[1],[2] The American Society of Anesthesiologists (ASA) difficult airway taskforce recommends that a VL be available as a first rescue device for all patients being intubated.[3]. Various studies have found that VL improves the ability to visualize the larynx and improves the intubation success.[4],[5],[6],[7]

Over the last two decades, a number of VL have emerged offering several advantages over direct laryngoscopy. McGrath MAC video laryngoscope has a slim disposable transparent regularly shaped blade similar to the Macintosh blade and a wide LCD screen attached to the handle. It is lighter in weight and has a more compact screen and handle which may make tracheal intubation easier and faster.[8] Trueview video laryngoscope has an integrated optical lens system with unique angulated blade which provides optimal indirect view of the glottis.[9]

This trial was conducted to compare the effectiveness of McGrath MAC video laryngoscope, Truview video laryngoscope and Macintosh laryngoscope when performing endotracheal intubation in patients undergoing surgery under general anesthesia.


   Methods Top


After obtaining approval from the institutional ethical committee and registration under the clinical trial registry of India (CTRI/2018/05/014150) this prospective randomized study was conducted over a period of 1 year. A total of 120 patients in the age 20–70 years of either sex, with ASA physical status Classes I or II scheduled for undergoing elective surgery requiring tracheal intubation were randomly assigned to McGrath MAC, Truview or Macintosh laryngoscope, to compose equal groups of 40 each. All intubations were performed by senior anesthesiologist who had experience of at least 40 intubations in patients using video laryngoscope.

Patients were divided into three groups:

  • Group 1 (n = 40) – patients in this group were intubated using McGrath MAC video laryngoscope
  • Group 2 (n = 40) – patients in this group were intubated using Truview video laryngoscope
  • Group 3 (n = 40) – patients in this group were intubated using Macintosh laryngoscope.


Preanesthetic checkup of all the patients was done 1 day prior to surgery which included detailed history, thorough physical examination (general and systemic), and basic relevant investigations. After obtaining consent from patients, tablet pantoprazole 40 mg and tablet alprazolam 0.25 mg were given to patients night before the surgery and on the morning of the surgery. Patients were kept fasting for 8 h before the surgery.

After arrival in the preoperative room, an intravenous catheter of 18G or 20G was secured and intravenous ringer lactate started at 60 ml/h. The patients were then shifted to the operation theater. In the operation theater, standard monitoring was done using: Continuous electrocardiograph (lead II), SpO2, noninvasive blood pressure and ETCO2.After preoxygenation, standard general anesthetic technique was followed in all the three groups using injection fentanyl 1.5 μg/kg intravenously, injection propofol 2 mg.kg−1 intravenously and neuromuscular blockade achieved with injection succinylcholine 1 mg.kg−1 intravenously and intubation was attempted after 60 s of injection succinylcholine.

All the intubations were done by the same experienced anesthesiologist and the head was kept in “neutral position.” Stylet was used for intubation in all the three groups. Size 3 of Macintosh blade and McGrath MAC blade and medium sized Truview blade for patients having weight up to 50 kg and size 4 of Macintosh blade and McGrath MAC blade and large-sized Truview blade for patients having >50 kg weight was used. After successful intubation, anesthesia was maintained using 66% nitrous oxide, 33% oxygen, and varying concentrations of isofluorane (1%–1.5%). Neuromuscular blockade was maintained with rocuronium 0.15 mg/kg. About half an hour before the end of surgery injection ondanseteron 0.1 mg.kg−1 intravenously was given to the patient. At the end of surgery, neuromuscular blocks were reversed with– injection neostigmine 0.05 mg.kg−1 and injection glycopyrolate 0.01 mg/kg. Various parameters were recorded:

  1. Duration of laryngoscopy was defined as oral placement of the laryngoscope blade to obtaining the best glottic view


  2. Evaluation of glottic view using Cormack and Lehane grading


    • Grade I visualization of entire vocal cords
    • Grade II visualization of posterior part of the laryngeal aperture
    • Grade III visualization of epiglottis only
    • Grade IV no glottic structures seen.


  3. Duration of intubation was defined as time interval between placements of endotracheal tube (ETT) between the dental arches to the first deflection on capnograph
  4. Ease of intubation: was graded as


Grade 1: intubation easy

Grade 2: intubation requiring an increased anterior lifting force and assistance to pull the right corner of the mouth upwards to increase space

Grade 3: intubation requiring multiple attempts

Grade 4: failure to intubate with the assigned laryngoscope.

An attempt was defined as the time from introduction of laryngoscope into the oral cavity until its removal. Three attempts at intubation were allowed for all groups. Failure to intubate was defined as the inability to intubate after three attempts. Alternative technique was used in case of failure as per the discretion of anesthesiologist.

Number of optimization maneuvers required like use of bougie, cricoid pressure, and second assistant were recorded. After intubation blade of laryngoscope was checked for blood staining and inspection of teeth and soft tissue was done to rule out trauma.


   Results Top


Data from 120 patients were analyzed. Patients in the three groups were comparable with respect to the baseline demographic characteristics as depicted in [Table 1].
Table 1: Demographic data of patients

Click here to view


[Figure 1] shows the duration of laryngoscopy which was significantly less in McGrath MAC group when compared to Truview group (3.92 vs. 4.62 s; P = 0.02) and to Macintosh group (3.92 vs. 5.75 s; P = 0.001, respectively. Duration of laryngoscopy was also significantly less in Truview group when compared to Macintosh group (4.62 vs. 5.75 s; P = 0.001).
Figure 1: Histogram showing mean duration of laryngoscopy

Click here to view


Duration of intubation was comparable between McGrath MAC and Truview (6.55 vs. 6.67 s; P = 0.73) group, between McGrath MAC and Macintosh (6.55 vs. 7.15 s; P = 0.15) groups and between Truview and Macintosh (6.67 vs. 7.15 s; P = 0.22) groups [Figure 2].
Figure 2: Histogram showing mean duration of intubation

Click here to view


[Table 2] shows Cormack Lehane Grade I was observed in 37 (92.50%) patients of McGrath MAC group, 35 (87.50%) in Truview group and 24 (60%) in Macintosh group. Grade II was observed in 3 (7.50%) patients in McGrath MAC group, 5 (12.50%) patients in Truview group and 7 (17.50%) in Macintosh group, whereas Grade III and IV were observed in 6 (15%) and 3 (7.50%) patients, respectively, in Macintosh group. Statistically, the difference was not significant between McGrath MAC and Truview groups (P = 0.71). However, between McGrath MAC and Macintosh and Truview and Macintosh groups, the difference was highly significant (P = 0.002 for each).
Table 2: Comparison of three groups in CLG, ease of intubation, number of attempts, optimization maneuvers and trauma caused

Click here to view


Intubation was easy in 36 (90%) patients in McGrath MAC group, 35 (87.50%) patients in Truview group and 26 (65%) patients in Macintosh group. Statistically, the difference in ease of intubation was better in McGrath MAC and Truview groups compared to Macintosh group (P < 0.05). Intubation was successful in the first attempt in 39 (97.50%) patients in McGrath MAC group, 40 (100%) patients in Truview group, and 35 (87.50%) patients in Macintosh group. Statistically, the difference of number of attempts at intubation was comparable among the three groups (P > 0.05).

The use of optimization manoeuvres such as bougie, cricoid pressure, and second assistant was required in 4 (10%) patients in McGrath MAC group, 5 (12.50%) patients in Truview group, and 14 (35%) patients in Macintosh group. Trauma was observed in 2 (5%) patients in Truview group and 5 (12.50%) patients in Macintosh group. In McGrath MAC group, no patient underwent any trauma. Statistically, the difference among the three groups was not significant (P > 0.05).


   Discussion Top


In the present study, duration of laryngoscopy was significantly less in McGrath MAC group as compared to Truview (P = 0.02) and Macintosh (P < 0.0001) groups. Similarly, duration of laryngoscopy was also significantly less in Truview group when compared to Macintosh group (P < 0.001). This was possible as Cormack and Lehane Grade I was achieved in maximum number of patients with both the video laryngoscopes compared to the conventional laryngoscope. Truview video laryngoscope gives a smaller field of vision, where the image of the vocal cords has to be focused on the prism to get the correct view which takes a few seconds, whereas McGrath video laryngoscope has an LCD screen which gives a clear image of the vocal cords and the surrounding anatomy with a larger field of vision.[5] Hence, McGrath video laryngoscope took a lesser time compared to Truview video laryngoscope. Furthermore with a direct laryngoscope it is necessary to obtain a line of sight from the maxillary teeth to the glottis whereas with the use of video laryngoscope the image of glottis is captured near the tip of the blade, only a few centimeters of line of sight is required and the need to align the oral, pharyngeal, and laryngeal axes is not there.[10],[11],[12]

Time taken to successfully intubate was less in McGrath MAC laryngoscope (6.55s) compared to Truview (6.67 s) and Macintosh (7.15 s) laryngoscopes. However, difference in time to intubate was statistically not significant between the three groups (P > 0.05). Although the duration of laryngoscopy was shorter in McGrath group as compared to other groups, the duration of intubation was comparable because while using the McGrath video laryngoscope, laryngeal axes are not aligned, and the tip of the tracheal tube must therefore pass around a relatively acute angle to enter the larynx. Second less space is created for tube insertion when using the McGrath, as the pharyngeal tissues are not displaced as far anteriorly as during direct laryngoscopy.[13] In a study Kim et al. found that the mean intubation times with McGrath MAC VL was less and did not differ significantly from those obtained with the GlideScope Ranger or the Macintosh in easy as well as difficult airway scenario, while Arora et al. reported that duration of intubation was less in Truview laryngoscope than Macintosh laryngoscope, though the difference was not statistically significant.[14],[15] Few studies found that intubation time using McGrath video laryngoscope was more as compared with Macintosh laryngoscope.[10],[11],[16] The reason cited was that although video laryngoscopes offer superior visualization of the glottis, a good laryngeal view does not guarantee easy or successful tracheal tube insertion. All video laryngoscopes without an integrated guide channel for the ETT could face the challenge of advancing the tube into the trachea as the tip of the tracheal tube must pass through an acute angle to enter the larynx and has significant potential of coming in contact with the anterior tracheal wall.[5] Furthermore, contrary to our observation, Barak et al. and Nasim et al. found that Truview EVO2 laryngoscope took longer time for intubation than Macintosh laryngoscope.[17],[18] This may be due to the greater experience of anesthesiologists with the Macintosh blade. Although the anesthesiologists who participated in these studies had practiced with the Truview blade several times prior to starting the study, their experience with the new device was less than that with the Macintosh blade.

In the present study, Cormack Lehane grading was statistically significant in McGrath and Truview as compared to Macintosh (P = 0.002), whereas it was comparable between McGrath and Truview groups. Video laryngoscopes provide better glottis exposure compared to direct laryngoscope and thus leading to a better Cormack and Lehane grading. This is attributed to the availability of camera on the blade tip of video laryngoscope that eliminates the need to align the oral, pharyngeal and laryngeal axes which is not the case with direct laryngoscope.[10],[11],[12]

In the present study, ease of intubation was significantly better in McGrath MAC group and Truview group as compared to Macintosh group (P < 0.05). For optimal visualization of the glottis with direct laryngoscope, the anterior structures of the larynx are elevated while the video laryngoscopes are designed to enable indirect laryngoscopic view and do not require much manipulation by the anesthesiologist to visualize the glottis and thus makes the job easier. This result is also similar to previous reported by other studies who also found that there was higher percentage of glottis opening in McGrath video laryngoscope group compared to Macintosh group (P = 0.002).[19],[20]

Intubation was successful in the first attempt in 39 (97.50%) patients in McGrath MAC group, 40 (100%) patients in Truview group and 35 (87.50%) patients in Macintosh group in the present study. Statistically, the difference of number of attempts at intubation was comparable among the three groups (P > 0.05). In a study conducted by Bhola et al., no second attempt was required in McGrath group, but in Truview group, two patients needed a second attempt.[5] The results of their study were not statistically significant. Barak et al. reported 100% success rate with Truview and 90% with Macintosh group, which is almost similar to this study.[17]

Regarding the use of optimization maneuvers, McGrath MAC and Truview groups performed better as compared to Macintosh group (P < 0.05). With direct laryngoscopy to visualize the glottis oral, pharyngeal and laryngeal axes need to be in straight line and thus much manipulation is required to achieve this. Furthermore, it is difficult to continuously maintain the glottis view till the intubation is done and thus more number of patients requiring the specific maneuvers.

In the present study, trauma was observed in 2 (5%) patients in Truview group and 5 (12.50%) patients in Macintosh group. In McGrath MAC group, no patient underwent any trauma. Statistically, the difference among the three groups was not significant (P > 0.05). Direct laryngoscopy might require the anesthesiologist to put undue pressure on gums, teeth, and periglottic structures for maximal exposure of vocal cords, thus leading to trauma. Bhola et al. (2014) also found that none of the patients in McGrath group experienced trauma, whereas in Truview group, two patients had gingival bleed as a complication of laryngoscopy.

The main limitation of our study is that anesthesiologist performing the laryngoscopy and intubation could not be blinded to the devices used in the study. Furthermore, there is a learning curve for VLs as all the anesthesiologists are mainly trained to use Macintosh laryngoscope.


   Conclusion Top


Inspite of duration of laryngoscopy being significantly shorter in McGrath as compared to Truview video laryngoscope and Macintosh laryngoscope, the duration of intubation was comparable between the three groups as it took longer to negotiate the ETT into the trachea. Laryngoscopic view as assessed by the Cormack and Lehane grading was improved in both the video laryngoscope groups. Both these video laryngoscopes performed significantly better than Macintosh laryngoscope with respect to the ease of intubation, requirement of optimization maneuver and need for second attempt for intubation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Chang CJ, Ming HS. Role of video laryngoscopy in the management of difficult intubations in the emergency department and during prehospital care. Tzu Chi Med J 2012;24:100-3.  Back to cited text no. 1
    
2.
Lewis SR, Butler AR, Parker J, Cook TM, Schofield-Robinson OJ, Smith AF. Videolaryngoscopy versus direct laryngoscopy for adult patients requiring tracheal intubation: A Cochrane Systematic Review. Br J Anaesth 2017;119:369-83.  Back to cited text no. 2
    
3.
Bakshi SG, Vanjari VS, Divatia JV. A prospective, randomised, clinical study to compare the use of McGrath(®), Truview(®) and Macintosh laryngoscopes for endotracheal intubation by novice and experienced Anaesthesiologists. Indian J Anaesth 2015;59:421-7.  Back to cited text no. 3
[PUBMED]  [Full text]  
4.
Su YC, Chen CC, Lee YK, Lee JY, Lin KJ. Comparison of video laryngoscopes with direct laryngoscopy for tracheal intubation: A meta-analysis of randomised trials. Eur J Anaesthesiol 2011;28:788-95.  Back to cited text no. 4
    
5.
Bhola R, Bhalla S, Gupta R, Singh I, Kumar S. Tracheal intubation in patients with cervical spine immobilization: A comparison of McGrath(®) video laryngoscope and Truview EVO2(®) laryngoscope. Indian J Anaesth 2014;58:269-74.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Bakshi SG, Gawri A, Divatia JV. McGrath MAC video laryngoscope versus direct laryngoscopy for the placement of double-lumen tubes: A randomised control trial. Indian J Anaesth 2019;63:456-61.  Back to cited text no. 6
[PUBMED]  [Full text]  
7.
Reena. Comparison of King Vision video laryngoscope (channeled blade) with Macintosh laryngoscope for tracheal intubation using armored endotracheal tubes. J Anaesthesiol Clin Pharmacol 2019;35:359-62.  Back to cited text no. 7
[PUBMED]  [Full text]  
8.
Shin M, Bai SJ, Lee KY, Oh E, Kim HJ. Comparing McGRATH® MAC, C-MAC®, and macintosh laryngoscopes operated by medical students: A randomized, crossover, manikin study. Biomed Res Int 2016;2016:8943931.  Back to cited text no. 8
    
9.
Bag SK, Kumar VR, Krishnaveni N, Ravishankar M, Velraj J, Aruloli M. A comparative study between Truview (PCD) laryngoscope and Macintosh laryngoscope in viewing glottic opening and ease of intubation: A crossover study. Anesth Essays Res 2014;8:372-6.  Back to cited text no. 9
  [Full text]  
10.
Savoldelli GL, Schiffer E, Abegg C, Baeriswyl V, Clergue F, Waeber JL. Comparison of the glidescope, the McGrath, the airtraq and the macintosh laryngoscopes in simulated difficult airways*. Anaesthesia 2008;63:1358-64.  Back to cited text no. 10
    
11.
Piepho T, Weinert K, Heid FM, Werner C, Noppens RR. Comparison of the McGrath® Series 5 and GlideScope® Ranger with the Macintosh laryngoscope by paramedics. Scand J Trauma Resusc Emerg Med 2011;19:4.  Back to cited text no. 11
    
12.
Burdett E, Ross-Anderson DJ, Makepeace J, Bassett PA, Clarke SG, Mitchell V. Randomized controlled trial of the A.P. Advance, McGrath, and Macintosh laryngoscopes in normal and difficult intubation scenarios: A manikin study. Br J Anaesth 2011;107:983-8.  Back to cited text no. 12
    
13.
Shippey B, Ray D, McKeown D. Case series: The McGrath videolaryngoscope – An initial clinical evaluation. Can J Anaesth 2007;54:307-13.  Back to cited text no. 13
    
14.
Kim W, Choi HJ, Lim T, Kang BS. Can the new McGrath laryngoscope rival the GlideScope Ranger portable video laryngoscope? A randomized manikin study. Am J Emerg Med 2014;32:1225-9.  Back to cited text no. 14
    
15.
Arora S, Sayeed H, Bhardwaj N. A comparison of Truview EVO2 laryngoscope with Macintosh laryngoscope in routine airway management: A randomized crossover clinical trial. Saudi J Anaesth 2013;7:244-8.  Back to cited text no. 15
    
16.
Maharaj CH, McDonnell JG, Harte BH, Laffey JG. A comparison of direct and indirect laryngoscopes and the ILMA in novice users: A manikin study. Anaesthesia 2007;62:1161-6.  Back to cited text no. 16
    
17.
Barak M, Philipchuck P, Abecassis P, Katz Y. A comparison of the Truview blade with the Macintosh blade in adult patients. Anaesthesia 2007;62:827-31.  Back to cited text no. 17
    
18.
Nasim S, Maharaj CH, Butt I, Malik MA, O' Donnell J, Higgins BD, et al. Comparison of the Airtraq and Truview laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation in manikins. BMC Emerg Med 2009;9:2.  Back to cited text no. 18
    
19.
Arici S, Karaman S, Doǧru S, Karaman T, Tapar H, Özsoy AZ, et al. The McGrath Series 5 video laryngoscope versus the Macintosh laryngoscope: A randomized trial in obstetric patients. Turk J Med Sci 2014;44:387-92.  Back to cited text no. 19
    
20.
Sachidananda R, Umesh G, Shaikh SI. A review of haemodynamic response to the use of different types of laryngoscopes. Anaesth Pain Intensive Care 2016;20:201-8.  Back to cited text no. 20
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Methods
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed935    
    Printed64    
    Emailed0    
    PDF Downloaded47    
    Comments [Add]    

Recommend this journal