Anesthesia: Essays and Researches  Login  | Users Online: 112 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size
Home | About us | Editorial board | Ahead of print | Search | Current Issue | Archives | Submit article | Instructions | Copyright form | Subscribe | Advertise | Contacts
ORIGINAL ARTICLE
Year : 2020  |  Volume : 14  |  Issue : 4  |  Page : 632-637

Effect of use of high-flow nasal cannula during fiberoptic intubation under general anesthesia: A randomized controlled trial


Department of Anesthesia and Critical Care, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh, India

Correspondence Address:
Dr. Manoj Tripathi
Department of Anesthesia and Critical Care, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, Uttar Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/aer.aer_55_21

Rights and Permissions

Background: Oxygenation by high-flow nasal cannula (HFNC) is being widely studied in the intensive care unit and operation theater settings. Aims and Objectives: The aim of this study is to determine the effect of HFNC during fiberoptic intubation in terms of time taken and ease of intubation. Settings and Design: Randomized, prospective, and controlled study. Materials and Methods: In this study, we have recruited 40 patients according to the inclusion criteria (patient's body mass index [BMI] >22.99 kg.m−2 and patients with a history of stridor and/or obstructive sleep apnea) and after randomization divided them into two groups of 20 each – Group C: Intubation done with conventional fiberoptic after muscle relaxation and Group S: Intubation done with high flow nasal cannula during fiberoptic after muscle relaxation. We have observed and compared between the groups time taken for intubation, oxygen saturation during fiberoptic intubation, need of jaw thrust and difficulty in gliding endotracheal tube over fiberscope. Results: No significant difference was found in time taken for intubation, oxygen saturation, and need of jaw thrust (P > 0.05). We have found a significant difference in gliding of endotracheal tube over fiberscope (P = 0.001). Conclusion: We found high flow nasal cannula better and beneficial in patients with high BMI and having a history of stridor/obstructive sleep apnea for fiberoptic intubation after muscle relaxation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed156    
    Printed0    
    Emailed0    
    PDF Downloaded20    
    Comments [Add]    

Recommend this journal